Power Cords Supplier, Manufacturer In China

EVE, EVJE

EVE, EVJE, TPE Insulated EV Charging Cable, 600V and 300V

Types EVE and EVJE are the thermoplastic elastomer versions of the UL 62 EV charging cable, and the letter J is the only structural difference between them: EVJE is the 300V type and EVE is the 600V type. Both use colour coded 105°C TPE insulation and a black 105°C TPE jacket over 18AWG to 6AWG fully annealed stranded copper, and both stay flexible from -50°C up to 105°C dry with a 60°C wet rating, passing the UL VW-1 vertical flame test. The TPE jacket is lighter than a PVC jacket at the same gauge, resists abrasion, oil and chemicals better, and can be bonded to the connector overmould, which is why it is the usual choice for commercial charging leads and outdoor installations.
No.of Core:3 power cores plus ground, signal cores optional
Electrical Voltage:600V (EVE), 300V (EVJE)
Temperature:-50°C to +105°C, 60°C wet
Approvels:UL, cUL Certified
Power Cable Standards :UL 62; UL 2263; CSA C22.2 No. 49

Our EVE, EVJE Power Cable products are fully molded with a low profile ergonomic design and RoHS, REACH and PAHS compliant.

Certainly! If you're looking for EVE, EVJE, We are your best choice.

EVE, EVJE Available Cord / Cables Wire Styles

Type / Voltage Conductors Insulation Jacket Nominal OD, 18AWG to 12AWG / 10AWG to 2AWG
EVJE, 300V 3C + 1C ground, 18AWG - 12AWG TPE 0.76mm plus 0.76mm on the ground Black TPE, 0.76 - 1.14mm 7.8mm at 18AWG to 11.6mm at 12AWG
EVE, 600V 3C + 1C ground, 18AWG - 2AWG TPE 1.14mm plus 0.76mm, 1.52mm above 8AWG Black TPE, 2.03 - 2.79mm 12.8mm at 18AWG to 28.5mm at 2AWG
105°C dry, 60°C wet, -50°C cold. UL VW-1 vertical flame test. Signal cores optional.
This cable can also be supplied in other lengths, colors and jacket compounds. See how to customize a power cord.

Product Description of EVE, EVJE

Number of Poles and Wires:
3 power cores plus ground, signal cores optional
Power Cables Standard:
UL 62; UL 2263; CSA C22.2 No. 49
Rated Voltage:
600V (EVE), 300V (EVJE)
Rated Temperature:
-50°C to +105°C, 60°C wet
Certified:
UL, cUL
Copper Conductor Material:
Oxygen free Copper (OFCU)
Outer Jacket Material:
TPE
Core Structure:
Cores twisted together
Flamability Rating:
UL 94V-0
Color
Black / White are standards, but any color available customized
Environmental Certifications:
RoHS, Reach, PAHs
Country of Origin:
Made In China
Packing:
Standard Export Carton

Specifications of American UL EV Charging Cables:

American UL EV Charging Cables

American UL EV Charging Cables

More details of EVE, EVJE for reference:

EVE, EVJE of  American UL EV Charging Cables

EVE, EVJE of American UL EV Charging Cables

EVE, EVJE of  American UL EV Charging Cables

EVE, EVJE of American UL EV Charging Cables

EVE, EVJE of  American UL EV Charging Cables

EVE, EVJE of American UL EV Charging Cables

EVE, EVJE of  American UL EV Charging Cables

EVE, EVJE of American UL EV Charging Cables

EVE, EVJE of  American UL EV Charging Cables

EVE, EVJE of American UL EV Charging Cables

EVE, EVJE of  American UL EV Charging Cables

EVE, EVJE of American UL EV Charging Cables

Related Products

Frequently Asked Questions

Common questions about this flexible power cable

Voltage. EVJE is the 300V version of the type and EVE is the 600V version; the J is the only change in the designation. Both use the same thermoplastic elastomer insulation and black TPE jacket at 105°C and the same 18AWG to 6AWG conductor range, so the choice follows the system voltage of the charger.

Cold flexibility, abrasion and chemical resistance. The TPE types hold their flexibility down to -50°C instead of -40°C, resist oils and chemicals better, and the jacket can be bonded to the connector overmould, which is why commercial charging leads and outdoor installations usually take the TPE version.

-50°C to +105°C with a 60°C wet rating, and the cable passes the UL VW-1 vertical flame test. The 60°C wet figure is the number to check for cables that stay outdoors or in an unheated car park.

The usual layout is three power conductors plus one ground conductor, with optional signal cores for the pilot and proximity circuits. Conductor sizes run 18AWG to 6AWG fully annealed stranded copper to ASTM B3 and B-174.

UL 62 lists the EV charging cable types, and EV cable is also listed under UL 2263 with CSA C22.2 No. 49 structures. North American EVSE equipment is covered by NEC article 625, and the vehicle connector interface is defined by SAE J1772.